Product Identification
Product ID:RYKON PREMIUM GREASE 2
MSDS Date:08/25/1989
FSC:9150
NIIN:00F019265
MSDS Number: BLPTL
Responsible Party
CHICAGO, IL 60601
Emergency Phone: (800) 447-8735
Info Phone: (312) 856-3907
Preparer: R G FARMER
Cage: 15958
Contractor
Telephone: 800 447-8735
Cage: 15958
Ingredients
SOLVENT REFINED HYDROTREATED HEAVY PARAFFINIC DISTILLATE,
CAS: 64742-54-7
RTECS: PY8035500
OSHA PEL 5 MG/CUM (MIST)
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED HEAVY
CAS: 64741-88-4
RTECS: PY8040500
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE EXPECTED UNDER NORMAL CONDITIONS
OF USE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE EXPECTED UNDER NORMAL CONDITIONS OF USE.
First Aid
First Aid:EYES: FLUSH W/PLENTY OF WATER. INGESTION: INDUCE VOMITING.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Extinguishing Media:AGENTS APPROVED FOR CLASS B HAZARDS SUCH AS DRY
CHEMICAL, CO2, HALOGENATED AGENTS, FOAM, STEAM OR WATER FOG.
Accidental Release
Spill Release Procedures:CONTAIN & REMOVE BY MECHANICAL MEANS.
Handling
Handling and Storage Precautions:AS REQUIRED.
Exposure Controls
Eye Protection:RECOMMENDED
Supplemental Safety and Health
ALL OF THE COMPONENTS OF THIS PRODUCT ARE LISTED ON THE TSCA INVENTORY.
THIS PRODUCT IS ACCEPTABLE TO THE USDA FOR USE AS A LUBRICANT IN
OFFICIAL MEAT & POULTRY ESTABLISHMENTS AVOIDING CONTAMINATION O F
EDIBLE PRODUCTS.
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:490F
Solubility in Water:NEGLIGIBLE, <0.1%
Appearance and Odor:RED COLORED SMOOTH TEXTURED GREASE.
Stability
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CO, CO2 & OTHER HARMFUL PRODUCTS.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS. ENCLOSED-CONTROLLED INCINERATION IS
RECOMMENDED UNLESS DIRECTED OTHERWISE BY APPLICABLE ORDINANCES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.